This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Villa, P
Right arrow Articles by Aznar, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Villa, P
Right arrow Articles by Aznar, J
Haematologica, Vol 85, Issue 5, 520-524
Copyright © 2000 by Ferrata Storti Foundation


Comparative Study

Quantification of D-dimer using a new fully automated assay: its application for the diagnosis of deep vein thrombosis

P Villa, F Ferrando, J Serra, H Faus, Y Mira, A Vaya, and J Aznar

Department of Clinical Pathology, La Fe University Hospital, Valencia Spain.

BACKGROUND AND OBJECTIVE: A D-dimer assay can be helpful to rule out thromboembolism provided it is sensitive, reliable, fast and easy to perform. Tests based on the ELISA methodology have a high diagnostic sensitivity, and are therefore adequate for excluding deep venous thrombosis (DVT). The drawbacks are their long assay times, unsuitability to be run on single samples and cost. New methods have been developed, based either on the same principle, by immunofiltration or by microlatex immunoturbidimetric assays which seem to reach the high sensitivity and negative predictive value (NPV) required, but allowing fast and quantitative single sample analysis. The aim of this work was to evaluate one rapid test, a fully automated quantitative assay (IL Test D-dimer, run on an ACL 7000 coagulation analyzer, Instrumentation Laboratory). DESIGN AND METHODS: We compared the diagnostic value of IL Test for DVT with that of an ELISA (Dimertest Gold EIA Agen Biomedical Limited, Acacia Ridge, Australia). Eighty-six patients (43 men, 43 women, mean age: 61 years) showing DVT symptoms formed the population for this non-randomized controlled trial in a referral center. The diagnosis of DVT based on the clinical history, was confirmed by serial compression ultrasonography (CUS) with Doppler flow in 62 patients. RESULTS: The IL Test D-dimer proved to be rapid, automated and well suited for individual tests with a good reproducibility in three control plasmas with different concentrations of D-dimer (coefficient of variation range 0.54-3. 87%). Its performance was comparable to that of the Dimertest Gold EIA, as indicated by the areas under the receiver operating characteristic curves (Dimertest Gold EIA 0.748; IL Test D-dimer 0.70). On the basis of kappa coefficients, there was a good concordance between the Dimertest Gold EIA and IL Test D-dimer when the receiver operating characteristic (ROC) curves suggested cut-offs were used. The sensitivity (98.3%) and NPV (88.9%) shown by IL Test D-dimer are comparable or even better than those obtained for EIA (95%, 80%, respectively). INTERPRETATION AND CONCLUSIONS: This study shows that the new method can be included in prospective clinical trials to test the utility of D-dimer measurement in combination with other non-invasive diagnostic procedures in the management of DVT diagnosis.


This article has been cited by other articles:


Home page
BMJHome page
T. L Fancher, R. H White, and R. L Kravitz
Combined use of rapid D-dimer testing and estimation of clinical probability in the diagnosis of deep vein thrombosis: systematic review
BMJ, October 9, 2004; 329(7470): 821.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
S. W. Heim, J. M. Schectman, M. S. Siadaty, and J. T. Philbrick
D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis
Clin. Chem., July 1, 2004; 50(7): 1136 - 1147.
[Abstract] [Full Text] [PDF]


Home page
Emerg. Med. J.Home page
K. Hogg and R. Boyd
IL D-dimer test in the diagnosis of pulmonary embolism
Emerg. Med. J., July 1, 2003; 20(4): 368 - 369.
[Abstract] [Full Text] [PDF]