An improved method for lupus anticoagulant detection

I Alonso, F Vandermijnsbrugge, E Vanremoortele, C Bradstreet, A Efira, and B Cantinieaux

The diagnosis of lupus anticoagulant (LA) becomes difficult when there is a weak titer of LA antibodies. This study demonstrates that 20 minutes' incubation increases the sensitivity of the mixing test to diagnose LA by 23% and to suspect the antibodies by 66%.