Haematologica, Vol 92, Issue 5, 712-713 doi:10.3324/haematol.10766
Copyright © 2007 by Ferrata Storti Foundation
Evaluation of a new turbidimetric assay for von Willebrand factor activity useful in the general screening of von Willebrand disease
Montse Piñol*,
Miquel Sales*,,
Marta Costa*,
Alberto Tosetto^,
Maria Teresa Canciani#,
Augusto B. Federici#
* Biokit S.A., Lliçà dAmunt, Barcelona, Spain;
^ Department of Hematology and Hemophilia and Thrombosis Center San Bortolo Hospital, Vicenza, Italy;
# Angelo Bianchi Bonomi Hemophilia and Thrombosis Center, Department of Internal Medicine and Medical Specialties, IRCCS Foundation Maggiore Policlinico Hospital, Mangiagalli, Regina Elena and University of Milan, Italy
Correspondence: Miquel Sales, Biokit SA, Lliçà dAmunt, Barcelona, Spain. E-mail: msales{at}biokit.com

ABSTRACT
We evaluated a new assay (HemosIL
TMVWF Activity on ACL-Futura)
in the screening of VWD. Samples from healthy donors and previously
diagnosed VWD patients were blindly analyzed by this new activity
assay and standard VWF:RCo. Results agreed and both assays showed
a similar sensitivity for the screening of VWD.
Key words: von Willebrand factor, von Willebrand disease, von Willebrand factor activity, automated assay, latex immunoassay.
Von Willebrand disease (VWD), the most frequent inherited bleeding disorder, is caused by a deficiency and/or abnormality of the von Willebrand factor (VWF).1,2 The revised classification of VWD identifies two major categories, characterized by quantitative (types 1 and 3) or qualitative (type 2) VWF defects.2 The most common test of VWF activity, the assay of VWF:RCo together with VWF:Ag is traditionally considered the first step in the diagnosis of VWD, with the VWF:RCo/Ag ratio being recommended to discriminate type 1 from type 2A, 2B and 2M VWD.1,2 Given the complexities of the aggregometric test, several alternative laboratory methods have been proposed to measure VWF activity. Monoclonal antibody-based ELISA,3,4 Elisa-based VWF:RCo,5,6 rapid assays for VWF:RCo using coagulometers,7 and assays measuring the binding of VWF to collagen.8 The aim of this study was to evaluate the novel fully automated HemosILTMVWF Activity assay on the ACL-Futura automated coagulometer (Instrumentation Laboratory) as a potential screening test for the diagnosis of VWD.9,10 The assay uses latex sensitized with monoclonal antibodies (RFF VIII:R/1)3 directed against the platelet binding site of VWF (GPIb receptor). The activity of VWF is determined by measuring the increase of turbidity produced by the agglutination of the latex particles as a consequence of the interaction between the GPIb receptor of VWF and the monoclonal antibodies. The lower limit of linearity has been reported at 12.5IU/dL.9 A set of 57 normal controls and 70 VWD patients from two Hemophilia Centers were blindly analyzed in the R&D laboratory of Biokit with HemosILTMVWF:Ag, HemosILTMVWF Activity and VWF:RCo (Dade Behring) performed on an optical aggregometer. All methods were used to analyze samples which were then classified as normal or VWD type 1, 2, or 3 using the same criteria in both activity assays. The cut-off declared by the HemosIL based on ABO group was used to define normality or VWD, and the Activity/Antigen (Act/Ag) ratio was used to define quantitative (type 1) or qualitative (type 2) VWD using 0.7 as cut-off.1 Sample values below detectability were classified as type 3.
After classification and database lock, blindness was disclosed by the two Hemophilia Centers where the patient samples were classified according to the clinical and laboratory findings. Table 1 shows the mean VWF concentration in IU/dL±SD (standard deviation) obtained for each assay. The first column shows the Classification according to the Haemophilia Centers. Nine samples from the Vicenza group which correspond to type 1 according to the last classification scheme,2 are shown separately. The last columns show the mean Act/Ag ratios. The mean VWF:Ag value for the VWD type 3 samples was below detectability, hence this group is not shown in this Table. Comparing the mean values of the two activity assays, only the type 2A samples show a highly significant difference (p=0.0006). Comparing the mean values of the Act/Ag ratios for both activity assays, the HemosIL shows a higher Act/Ag ratio than the VWF:RCo for type 2A samples (p=0.002), while the other subtypes of VWD show no difference.
The comparison of HemosIL
TM VWF Activity to the reference method
VWF:RCo shows a Passing & Bablok fitted curve y=0.95x+1
and Pearson correlation of r=0.956 (
p<0.0001). The ability
of the activity assays as screening tests to distinguish between
VWD patients from non VWD was evaluated. One out of 70 VWD samples
which corresponded to a type1 VWD patient, was classified as
Normal by both activity assays. Thus the sensitivity for the
VWD was 98.6% for both. From the remaining 69 VWD samples which
resulted in a VWD type from both activity assays, we compared
their ability to discriminate between quantitative and qualitative
deficiencies.
Table 2 shows the classification according to
the HemosIL and the VWF:RCo assays for each group of samples.
Sensitivity for qualitative VWD was 94.7% (95%CI: 86.2%–99.9%)
for the HemosIL and 100% (95%CI:90.7%–100.0%) for the
VWF:RCo. Sensitivity for quantitative VWD was 71.0% (95%CI:52.0%–85.5%)
and 64.5% (95%CI:45.4%–80.8%) for the HemosIL and the
VWF:RCo respectively. The overall agreement was 84.1% for both
assays.
In conclusion, unlike other indirect tests based on monoclonal
antibodies against epitopes of VWF A1 domain,
3,4 the HemosIL
TMVWF
activity correlates with the standard VWF:RCo in all type 1
and 2 VWD variants. Compared with the classical aggregometric
assay for VWF:RCo, the new assay has the advantage of being
much faster and fully automated, although it has a sensitivity
limit of 12.5 IU/dL. HemosIL
TM VWF activity, in combination
with the HemosIL
TM VWF:Ag appears to be a useful screening tool
in the diagnostic evaluation of patients with a bleeding diathesis,
9,10 although additional VWF tests should always be performed to
confirm and further characterize diagnosis.

References
- Castaman G, Federici AB, Rodeghiero F, Mannucci PM. Von Willebrands disease in the year 2003: towards the complete identification of gene defects for correct diagnosis and treatment. Haematologica 2003;88:94-108.[Abstract/Free Full Text]
- Sadler JE, Budde U, Eikenboom JCJ, Favaloro EJ, Hill FGH, Holmberg L, et al. Update on the pathophysiology and classification of von Willebrand disease: a report of the Subcommittee on von Willebrand Factor. The Working Party on von Willebrand Disease Classification. J Thromb Haemost 2006;4:2103-14.[CrossRef][Web of Science][Medline]
- Murdock PJ, Woodhams BJ, Matthews KB, Pasi KJ, Goodall AH. von Willebrand factor activity detected in a monoclonal antibody-based ELISA: an alternative to the ristocetin co-factor platelet agglutination assay for diagnostic use. Thromb Haemost 1997;78:1272-7.[Web of Science][Medline]
- Preston FE. Assays for von Willebrand factor functional activity: a UK NEQAS survey. Thromb Haemost 1998;80:863.[Web of Science][Medline]
- Vanhoorelbeke K, Cauwenberghs N, Vauterin S, Schlammadinger A, Mazurier C, Deckmyn H. A reliable and reproducible ELISA method to measure ristocetin co-factor activity of von Willebrand factor. Thromb Haemost 2000;83:107-13.[Web of Science][Medline]
- Federici AB, Canciani MT, Forza I, Mannucci PM, Marchese P, Ware J, et al. A sensitive ristocetin co-factor activity assay with recombinant glycoprotein Ib
for diagnosis of patients with low von Willebrand factor levels. Haematologica 2004;89:77-85.[Abstract/Free Full Text] - Lattuada A, Preda L, Sacchi E, Gallo L, Federici AB, Rossi E. A rapid assay for ristocetin co-factor activity using an automated coagulometer (ACL 9000). Blood Coagul Fibrinol 2004;15:505-11.[CrossRef][Web of Science][Medline]
- Favaloro EJ. Collagen binding assay for von Willebrand factor (VWF:CBA): detection of von Willebrands disease (VWD), and discrimination of VWD subtypes, depends on collagen source. Thromb Haemost 2000;83:127-35.[Web of Science][Medline]
- De Vleeschauwer A, Devreese K. Comparison of a new automated von Willebrand factor activity assay with an aggregation von Willebrand ristocetin co-factor activity assay for the diagnosis of von Willebrand disease. Blood Coagul Fibrinol 2006;17:353-8.[Web of Science][Medline]
- Sucker C, Senft B, Scharf RE, Zotz RB. Determination of von Willebrand factor activity: evaluation of the HaemosILTM assay in comparison with established procedures. Clin Appl Thromb/Hemost 2006;12:305-10.[Abstract/Free Full Text]